Addressable Fire Systems
Addressable Fire Panel support 2100 addressable point total, with 4 line LCD display with 40 characters per line For IFP Module only , One SLC loop card in build, 159 Detectors and 159 Modules per loop, Additional Loop cards can be expanded through 5815RMK (Remote mounting Kit which accommodates 2 SLC Cards (6815)) , Network card allows copper network connection with a multi-mode or single-mode fiber connection option , Network up to 32 panels, Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC and SBUS, in build eight on-board Flexput™ circuits, Built in USB interface for programming, Four programmable function keys, 240VAC @ 50/60Hz, 2.8A , UL Listing and FM Approved, Red/Black Cabinet.
Addressable Fire Alarm Control Panel
IFP-2100 / IFP-2100B / RFP-2100 / RFP-2100B
Addressable Fire Panel support 2100 addressable point total, with 4 line LCD display with 40 characters per line For IFP Module only , One SLC loop card in build, 159 Detectors and 159 Modules per loop, Additional Loop cards can be expanded through 5815RMK (Remote mounting Kit which accommodates 2 SLC Cards (6815)) , Network card allows copper network connection with a multi-mode or single-mode fiber connection option , Network up to 32 panels, Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC and SBUS, in build eight on-board Flexput™ circuits, Built in USB interface for programming, Four programmable function keys, 240VAC @ 50/60Hz, 2.8A , UL Listing and FM Approved, Red/Black Cabinet.
Addressable Fire Alarm Control Panel with Evacuation
IFP-2100ECS / IFP-2100ECSB
Farenhyt 2100 Addressable point Integrated Fire Alarm & Emergency Communication System, 4 line LCD display with 40 characters per line, One SLC loop card in build, 159 Detectors and 159 Modules per loop, Additional Loop cards can be expanded through 5815RMK (Remote mounting Kit which accommodates 2 SLC Cards (6815)), Network up to 32 panels, in build eight on-board Flexput™ circuits, Built in USB interface for programming, Support for up to 16 addressable amplifiers using a combination of ECS-50W,ECS-INT50W or ECS-DUAL50W for a maximum of 2000 watts per system and up to 128 mappable speaker circuits, Four programmable function keys, 240VAC @ 50/60Hz, 2.8A , UL Listing and FM Approved, Red/Black Cabinet
Fire Fighter Telephone System
IFP-FFT
The IFP-FFT is a Fire Fighters Telephone communication system. The IFP-FFT Fire Fighter Telephone System provides supervision, annunciation, and control for local and remote telephone handsets. The IFP-FFT with keypad, provides indications of phone activation, and corresponding trouble conditions. The FFT-24 expander board lets you add additional zones to the IFP-FFT. The IFP-FFT can use up to two FFT-24’s for a total of 72 zones. Each zone consists of one addressable monitor module (IDP-Minimon) and a minimum of one Fire Fighter Telephone Jack (FFT-FPJ).
Fire Alarm Repeater Panel
RA-100
The RA-100 Remote Annunciator can be used to operate and program the Farenhyt Series Fire Control Panels. The remote annunciator connects to the control panel via the RS485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur
RA-1000
The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACP's). The RA-1000’s keypad and display match the built-in annunciator of the IFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur.
RA-2000 / RA-2000GRAY
The RA-2000 , 4x40, red remote annunciator can be used to operate and program the Honeywell Farenhyt Series FACP's. The remote annunciator connects to the control panel via the RS-485 SBUS. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, and system silenced occur. The RA-2000 can be surface or flush mounted and is also available in gray color as RA-2000GRAY.
ECS Power Amplifier
Intelligent 50 Watt Amplifier
ECS-50W / ECS-50WB
The ECS-50W (red cabinet) or ECS-50WB (black cabinet) is an intelligent 50 watt amplifier for use with the IFP-100ECS, IFP300ECS, IFP-1000ECS, IFP-2000ECS and IFP-2100ECS. The ECS-50W/ECS-50WB are used to amplify the audio message for distribution throughout the facility. Since it is designed as a self-contained distributed amplifier it can be conveniently located near the area of protection to reduce wiring demands. Each ECS-50W/ECS-50WB is capable of producing 50-watts of audio power. Up to eight ECS-50W’s can be used on the voice evacuation system. The ECS-50W/ECS-50WB has its own power supply with battery backup and four speaker circuits which can be expanded to eight speaker circuits with the optional ECS-CE4. The ECS-50W/ECS50WB is fully supervised by the main panel for trouble conditions.
Intelligent 125 Watt Amplifier
ECS-125W / ECS-125WB
The ECS-125W (red cabinet) or ECS-125WB (black cabinet) is an intelligent 125 watt amplifi er for use with the IFP-100ECS, IFP300ECS, IFP-1000ECS, IFP-2000ECS and IFP-2100ECS. The ECS-125W/ECS-125WB are used to amplify the audio message for distribution throughout the facility. Since it is designed as a self-contained distributed amplifi er it can be conveniently located near the area of protection to reduce wiring demands. Each ECS-125W is capable of producing 125-watts of audio power. Up to eight ECS-125Ws can be used on the voice evacuation system. The ECS-125W has its own power supply with battery backup and four speaker circuits which can be expanded to eight speaker circuits with the optional ECS-CE4. The ECS-125W is fully supervised by the main panel for trouble conditions.
Supervised Remote Command Unit
ECS-RCU
The ECS-RCU is a combination supervised remote microphone and annunciator which is compatible with the ECS-Series Emergency Communication System. The ECS-RCU meets UL requirements for a LOC. (Local Operator’s Console). The included ECS-RVM Remote Voice Module provides an interface to the Emergency Communication System and a supervised microphone for live communications. The annunciator is capable of performing complete operation of the fire alarm system, including silencing and resetting. The IFP-100ECS and IFP-1000ECS can support a maximum of seven ECS-RPUs or ECS-RCUs in any combination.
Remote Paging Unit
ECS-RPU
The ECS-RPU is a remote paging unit that provides a supervised microphone, 8 emergency message buttons, and 16 mappable audio switches. With dimensions of 17 ¾” x 11 7/16” x 3 ½”, this lower profile remote paging unit is ideal for locations where the standard LOC won’t fit. The RA-2000 and RA-100 have the same height and flush mount depth as the ECS-RPU so if your installation requires a fully functioning LOC with annunciation the RA-2000 or RA-100 can be installed right next to the ECS-RPU for a sleek installation. The IFP-100ECS and IFP-1000ECS can support a maximum of 7 ECS-RPUs or ECS-RCUs in any combination. The IFP-2000ECS can support a maximum of 15 ECS-RPUs or ECS-RCU2000s in any combination.
Intelligent Distributed Power Module
6 Amp Intelligent Distributed Power Module
RPS-1000 / RPS-1000B
RPS-1000 is an intelligent distributed power module that adds 6.0 amps of power, six Flexput™ I/O circuits, and two Form C relay circuits to a compatible Honeywell Farenhyt Series addressable system. The RPS1000 is available in a red (RPS-1000) or black (RPS-1000B) cabinet. The RPS- 1000 connects to the FACP via the RS-485 system bus allowing up to an additional 6,000 feet of wiring. Each RPS- 1000 is optically isolated providing ground loop isolation and transient protection. RPS1000 supports its own backup battery and monitors the AC power. The Flexput circuits can be programmed as notifi cation appliance circuits, continuous, re-settable, or door holder power, or as conventional initiation circuits for 2 or 4-wire smoke detectors and contact devices (e.g. pull stations).Installation.
IDP Detectors and Modules
Intelligent Photoelectric Smoke Detector and Photoelectric Smoke Detector with Thermal
IDP˜PHOTO / IDP˜PHOTO˜T / IDP˜PHOTOR
The IDP PHOTO is a photoelectric smoke detector and the IDP PHOTO T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with the Honeywell Farenhyt Series fire alarm control panels (FACPs).
The IDP PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. It is UL 268A listed when used with the DNR (W) duct smoke detector.0
- UL Listed
- FM Approved
- CSFM Listed
Intelligent Thermal and Rate of Rise Thermal Detectors
IDP˜HEAT/ IDP˜HEAT˜HT/ IDP˜HEAT˜ROR
The IDP Heat, IDP Heat HT, and IDP Heat ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Honeywell Farenhyt series fire alarm control panels (FACPs).
IDP Heat is a fixed temperature thermal detector that uses a thermistor sensing circuit to produce 135ºF (57ºC) fixed thermal detection.
IDP Heat HT is a variable high temperature detector that provides high temperature detection at 135ºF – 190ºF (57ºC – 88ºC).
IDP Heat ROR is a fixed temperature and rate-of-rise thermal detector that uses a thermistor sensing circuit to produce 135ºF (57ºC) thermal protection.
- UL Listed
- CSFM Listed
- MEA Listed 383fi02fiE Vol. VI
Addressable Beam Smoke Detector
IDP˜BEAM / IDP˜BEAM˜T
The IDP’BEAM and IDP’BEAM’T are addressable beam smoke detectors for use with Farenhyt Series fire alarm control panels (FACPs). They are uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. The
IDP’BEAM’T also includes an integrated sensitivity test feature.
- UL Listed
- CSFM Listed
- MEA Listed 95„01„E Vol. II
Intelligent NonRelay Duct Detector
DNR / DNRW
The DNR Intelligent non-relay photoelectric duct smoke detector housing and DNRW watertight non-relay photoelectric duct smoke detector housing (head not included) are for use with Honeywell Farenhyt Series fire alarm control panels (FACPs).
The DNR and DNRW feature a pivoting housing that is flexible enough to fit configurations from square to rectangular. They feature low-flow technology that enables duct smoke detection throughout a broad range of airflow environments. Many difficult to solve HVAC applications occur in low airflow duct applications where reliable smoke detection is critical. These duct detectors can detect smoke at air speed velocities of 100 feet per minute or greater, while continuing the same reliable performance to 4000 feet per minute.
- DNRW is listed as a watertight enclosure allowing for use in the most extreme environments
- UL 268A listed
- CSFM Listed
- MEA Listed -
225 02 E Vol. V
Addressable Single Action and Dual Action Pull Stations
IDP˜PULL˜SA / IDP˜PULL˜DA
The IDP PULL SA is a single action pull station requiring only one motion to activate the station. The IDP PULL DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Honeywell Farenhyt series fire alarm control panels (FACPs).
- UL Listed, including UL 38, Standard of Manually Actuated Signaling System
- CSFM Listed
- MEA Listed
Addressable Relay Module
IDP˜RELAY
The IDP RELAY is an addressable relay module for use with the Honeywell Farenhyt Series fire alarm control panels (FACPs).
The IDP RELAY allows a Farehyt FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit.
- UL Listed
- CSFM Listed
- MEA Listed 386⁄02⁄E Vol. II
Addressable Relay Module
IDP-Relay-6
The IDP-Relay-6 is an addressable relay module for use with Honeywell Farenhty Series fi re alarm control panels (FACPs). The IDPRelay-6 has six Form C relays. It allows a Farenhyt FACP to switch discrete contacts by code command. If needed, you can disable a maximum of three unused modules on the IDP-Relay-6 board. No supervision is provided for the notification appliance circuit.
- UL Listed
- CSFM Listed
- MEA Listed 386-02-E Vol. I
Addressable Notification Module
IDP˜CONTROL
The IDP CONTROL is an addressable notification module for use with Honeywell Farenhyt Series fire alarm control panels (FACPs). The IDP CONTROL gives you the flexibility to add notification circuits wherever they are needed on an Farenhyt FACP signaling line circuit (SLC) loop
The IDP CONTROL provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as bells, horns, and strobes. It is capable of Class B and Class A supervision.
- UL Listed
- CSFM Listed
- MEA Listed 386⁄02⁄E Vol. II
Addressable Monitor Module
IDP-Minimon
The IDP-Minimon is a compact and light weight addressable monitor module for use with Farenhyt Series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions.
Addressable Monitor Module
IDP-Monitor
The IDP-Monitor is an addressable monitor module for use with the Honeywell Farenhyt Series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such as water flow switches and pull stations. The IDP-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions
Addressable Dual Monitor Module
IDP-Monitor-2
The IDP-Monitor-2 is an addressable monitor module with two initiating circuits for use with Honeywell Farenhyt Series fi re alarm control panels (FACPs). The IDP-Monitor-2 acts as an interface to contact devices, such as waterfl ow switches and pull stations. The IDP-Monitor-2 supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Because the IDP-Monitor-2 is capable of monitoring two separate Class B circuits, it is ideal for waterfl ow tamper switch and fl ow switch monitoring.
Addressable Monitor Module
IDP-Monitor-10
The IDP-Monitor-10 is a 10 point addressable monitor module for use with the Honeywell Farenhyt Series fi re alarm control panels (FACPs). The IDP-Monitor-10 acts as an interface to contact devices, such as waterfl ow switches and pull stations. The multiple input design allows for easy and efficient installation. The IDP-Monitor-10 supports ten Class B supervised contact inputs or five Class A supervised contact inputs. Conventional 4- wire smoke detectors can be monitored for alarm and trouble conditions.
Addressable Two-Wire Interface Module
IDP-Zone
The IDP-Zone is an addressable two-wire interface module for use with the Honeywell Farenhyt Series fi re alarm control panels (FACPs). The IDP-Zone allows a Honeywell FACP to interface and monitor two-wire conventional smoke detectors. This means you can retrofit an existing building and use existing conventional devices. The IDP-Zone is addressed through the signaling line circuit loop of the FACP. It transmits the status of one full zone of two wire detectors to the FACP. Status conditions are reported as normal, open, or alarm. The IDP-Zone supervises the zone of detectors and the connection of the external power supply. All two-wire detectors being monitored must be UL compatible with the IDP-Zone.
Audible/Visual Notification
L-Series Indoor Horns, Strobes, and Horn Strobes
The L-Series audible visible notification products offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement
The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation.
L-Series Indoor Strobes, and Horn Strobes for Ceiling Applications
The L-Series audible visible notification products offer the most versatile and easy-to-use product line of horns, strobes, and horn strobes in the industry. This product includes lower current draws and modern aesthetics design which reduces installation times and maximizes profit. In adition, the L-Series offers white and red plastic housings, and wall and ceiling mounting options.
The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation.
L-Series Chimes and Chime / Strobes
The L-Series product line of wall and ceiling mount chimes and chime strobes include a variety of features that increase their application versatility while simplifying the installation. With white and red plastic housings, System Sensor L-Series can meet virtually any application requirement. Selectable-output chimes and chime/strobes are private mode notification appliances used to alert trained personnel to investigate possible emergency situations and to take appropriate action. Security guard and nurse workstations are ideal locations for chime product
L-series Indoor Wall Speakers Strobes and Speakers
The L-Series indoor selectable-output speaker strobes and dual-voltage speakers offer a modern, aesthetic plug-in design that deduce costly ground faults. The universal mounting plate can be used in wall installation applications and its flexible design enables the installer to easily perform the following, pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers.
L-Series Indoor Ceiling Speaker Strobes and Dual Speakers
The L-Series indoor selectable-output speaker strobes and dual voltage evacuation speakers offer a modern, aesthetic, plug-in design that reduces costly groud faults. The universal mounting plate can be used in ceiling applications and its flexable design enables the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers.
L-Series SPCW8, 8-Inch Dual Voltage Speaker
The SPCW8 8” speaker provides a solution for ceiling mount applications for tap setting range between 1/8 watt to 8 watts. Providing a solution for almost any voice need. System Sensor offers seven different tap settings ranging from 1/8 to 8 watts providing a solution for life safety and general signaling requirements. The high dB output reduces the number of speakers required for sound and intelligibility. The SPCW8 is designed for high efficiency sound output with low total harmonic distortion to offer high fidelity sound output.
SEP-SPSWL, SEP-SPSWL-P Dual Strobe Expander Plates
Dual Strobe Expander Plates SEP-SPSWL Expander Plate (as sold) SEP-SPSWL Expander Plate with Horn Strobe SEP-SPSWL Expander Plate with Speaker Strobe and Backbox Skirt General The new L-Series Universal Expander Plate for Dual Strobe and Dual Strobe with Speaker lowers costs and improves aesthetics by performing the functions of 2-3 devices for emergency communications applications.
L-Series Audible Visible Accessories